Monday, February 24, 2014

Troubleshooting the Astra Load Test Monitor

How the Monitor Works

The monitor will run the script in the Astra LoadTest (ALT) application. It is running through perfex, and will spawn an mdrv process to execute the script. Perfex is required so that the mdrv process will be created with the credentials supplied in the ALT Recorder page.

The script is run in exactly the same way as it is run under Astra LoadTest in load mode. Astra Load Test will use the credentials defined in the Recorder page.

The Astra LoadTest log files are kept in the SiteScope\cache\tempbysize directory. The monitor parses this log file to get the transaction times and errors/warnings. By default, SiteScope saves only the log files of failed runs. If the run finished successfully, the log is not saved. However If you want to keep all the log files, you have can open the SiteScope/groups/master.config file and set to "true" the following entry:

_astraKeepLogFiles=

How to Troubleshoot

1. Make sure you have Astra LoadTest version 5.4.3 or later. It must be installed on the same machine where SiteScope is running.

2. When setting up the script initially in ALT, you must define at least one Transaction while recording (with Start and Stop points), or the monitor will fail in SiteScope.

3. The credentials (in Recorder page) have to be the same as the user that was logged in when Astra LoadTest was installed.

4. Check that you can run the script in Astra LoadTest directly. If the script runs in Astra Load Test but times out in SiteScope, then use WinInet mode to execute the script instead. In order to switch between WinInet and Turbo replay you have to go to the RTS – Browser Configuration tab and check/uncheck the Use Turboload Technology option.

5. If you are running SiteScope service as a LocalSystem Account, add the user credentials located in the Astra LoadTest Runners Preference page. This is in the help manual at:

http://your SiteScope server name and port/SiteScope/docs/recorderPrefs.htm

SiteScope should run as an interactive service in the context of the LocalSystem account. It can be changed in Control Panel -> Services -> Sitescope -> Properties -> Log on. Select the Allow interaction with desktop checkbox.

6. Every time SiteScope restarts, it cleans up the oldest Astra LoadTest log files in the SiteScope/cache/tempbysize directory according to the max size limit defined for this directory in the SiteScope/groups/master.config file. The entry is:

_tempDirMaxSize=10000 (the size is in KB)

In SiteScope 7.8.1.0, there is no default value for that entry, and that will cause all the files in the directory to be deleted. There is a default of 10000 in SiteScope 7.8.1.2 and later. If the entry is not there, then add the above entry to the master.config file, save it, and restart SiteScope. After that, the log files should be kept until the directory gets to the limit defined.

Note – Astra Load Test has been deprecated as of SiteScope 7.9.0.0 or later. It is only available in these versions if SiteScope has been upgraded from a pre-7.9.0.0 version.

JMETER TIPS AND TRICKS

1. How to add JMeter requests manually and 
2.Need to capture the traffic for a web front end that’s heavy in AJAX. So there’s a lot going on in the background that I don’t get to see by just making a request to the page. I could use a third party app or an addon like Firebug to grab all the traffic but when that functionality is built into JMeter I’d just be making work for myself.

I have the bare bones of my test plan in place. In the test plan node I create a User Defined Variable called serverName with the relevant target server name as the value. I’m ready to record the transactions for a short user story. I create a blank transaction controller to group the page requests (this relates to another tip I’ll post later) then in the Proxy Server config I set the Target Controllerto this empty one.

Changing the proxy server and port in the browser, I point the browser at the required location and record the transaction. For the next step I create another empty Transaction Controller, update theTarget Controller of the Proxy Server, and continue with the user story, repeating this process for each step.

This can seem cumbersome but it lightens the work load. It also allows you to go back and edit the request, adding whatever assertions you feel may be warranted while the step is clerar in your mind. An alternative would be to set the Grouping on the Proxy Server to Put each group in a new controller and later copy and paste these grouped requests into transaction controllers seperately. Either way would work. Just don’t get too far ahead of yourself and record a large slice of your user story without analysing it.

Now if I go back and look at an HTTP request created during the user story, the Server Name or IPfield has been automatically filled with the appropriate variable i.e. ${serverName}. Any other variables I set are also automagically entered into their appropriate fields.