Monday, December 30, 2013

LR Controller online Graphs Directory to modify

1. By default, the Controller online monitor shows a maximum of 20 measurements for each graph. To increase it, go to the LoadRunner\dat\online_graphs directory to modify the value ofMaxDispMeasurments= in the file controlling each type of graph: 

2. Default counters for the System Resource, Microsoft IIS, Microsoft ASP, or SQL Server monitors are defined in the res_mon.dft file within the LoadRunner/dat folder. Its values can be pasted from the [MonItemPlus] section within scenario .lrs files.

Description File Name
All generalsettings.ini
System Resource Graphs online_resource_graphs.rmd
Runtime Graphs online_runtime_graphs.def
Transaction Graphs online_transaction_graphs.def
Web Resource Graphs online_web_graphs.def
Streaming Media online_web_graphs_mms.def